Skip to content
Sand Cone

Theory · TST-13 · Testing

Sand Cone Test – Field Density

How the sand cone measures a compacted soil's density in the field and how it compares with the Proctor test's in compaction control.

Enter the sand's calibration, the maximum dry density and optimum water content from the Proctor test, with the specification, and, at each point, the bottle's mass before and after, the mass of soil dug out and its water content, to get the hole's volume, the in-place dry density, the relative compaction and the moisture deviation at each point, per ASTM D1556.

The test

A base plate with a central hole is set on the compacted layer and a hole about 15 cm deep is dug through it, keeping all the soil removed. Through a cone with a valve, a clean, uniform sand of known density fills the hole; the mass that left the bottle, less what fills the cone and plate, gives the hole's volume.

In-place density

V=Mbefore−Mafter−MconeρsandV = \frac{M_{before} - M_{after} - M_{cone}}{\rho_{sand}}
ρ=MsoilV\rho = \frac{M_{soil}}{V}
ρd=ρ1+w\rho_d = \frac{\rho}{1 + w}
Mbefore, Mafter: the bottle with sand before and after · Mcone: the sand that fills the cone and plate · ρsand: from the calibration · Msoil: wet soil dug out · w: its water content, oven-dried or by a rapid method

Compaction control

RC=ρdρd,max×100RC = \frac{\rho_d}{\rho_{d,max}} \times 100
Δw=w−wopt\Delta w = w - w_{opt}
RC: relative compaction · ρd,max, wopt: from the Proctor test at the specified effort · Δw: moisture deviation

Specifications ask for a minimum relative compaction, such as 95% of the modified Proctor, and a water content near the optimum, such as ±2%. A point that falls short fails: the layer is compacted again, or its water corrected.

On this page

  • Tests per ASTM D1556; the Portuguese page follows ABNT NBR 7185. The calculations are the same.
  • ρd,max and wopt can come from a saved Proctor or CBR test, through links: from Proctor, the first curve's.
  • Without wopt or a deviation, the water content isn't checked.
  • Click a point on the charts to highlight it.

The 3D is an illustration of the apparatus and the hole, at a sand cone's usual sizes; it doesn't depend on the points tested.

Limitations

  • The sand must be calibrated as it's used, from the same height of fall; vibration near the hole densifies it and throws off the volume.
  • In gravelly soils the hole's walls mustn't cave in, and ρd,max must be the one of the material passing the same sieve.
  • The relative compaction stands only for the hole's depth; thicker layers need deeper holes.

References

  1. ASTM D1556/D1556M. Standard Test Method for Density and Unit Weight of Soil in Place by Sand-Cone Method. West Conshohocken: ASTM International.
  2. ASTM D698. Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Standard Effort. West Conshohocken: ASTM International.
  3. Das, B. M.; Sobhan, K. Principles of Geotechnical Engineering. 9th ed. Boston: Cengage, 2018.