Theory: Sand Cone
How the sand cone measures a compacted soil's density in the field and how it compares with the Proctor test's in compaction control.
The test
A base plate with a central hole is set on the compacted layer and a hole about 15 cm deep is dug through it, keeping all the soil removed. Through a cone with a valve, a clean, uniform sand of known density fills the hole; the mass that left the bottle, less what fills the cone and plate, gives the hole's volume.
In-place density
Compaction control
Specifications ask for a minimum relative compaction, such as 95% of the modified Proctor, and a water content near the optimum, such as ±2%. A point that falls short fails: the layer is compacted again, or its water corrected.
On this page
- Tests per ASTM D1556; the Portuguese page follows ABNT NBR 7185. The calculations are the same.
- ρd,max and wopt can come from a saved Proctor or CBR test, through links: from Proctor, the first curve's.
- Without wopt or a deviation, the water content isn't checked.
- Click a point on the charts to highlight it.
The 3D is an illustration of the apparatus and the hole, at a sand cone's usual sizes; it doesn't depend on the points tested.
Limitations
- The sand must be calibrated as it's used, from the same height of fall; vibration near the hole densifies it and throws off the volume.
- In gravelly soils the hole's walls mustn't cave in, and ρd,max must be the one of the material passing the same sieve.
- The relative compaction stands only for the hole's depth; thicker layers need deeper holes.
References
- ASTM D1556/D1556M. Standard Test Method for Density and Unit Weight of Soil in Place by Sand-Cone Method. West Conshohocken: ASTM International.
- ASTM D698. Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Standard Effort. West Conshohocken: ASTM International.
- Das, B. M.; Sobhan, K. Principles of Geotechnical Engineering. 9th ed. Boston: Cengage, 2018.