Skip to content

Triaxial Test (UU, CU and CD)

Pick the test (UU, CU or CD) and enter each specimen's dimensions, pressures and readings of axial displacement and load, with the pore pressure (CU) or volume change (CD), to get the stress-strain curves with the area corrected, each specimen's failure point, the stress paths, the Mohr circles and the envelope, with c′ and φ′ (and the total c and φ in a CU test), Skempton's A, E50 and, in a UU test, the undrained shear strength su.

SeriesStep #1

TestStep #2

Test type

Consolidated undrained, with pore pressure measured: effective and total stresses.

Failure criterion
Membrane correction

SpecimensStep #3

  • σ′3c
    100.0 kPa
    Ac
    11.13 cm²
  • σ′3c
    200.0 kPa
    Ac
    10.99 cm²
  • σ′3c
    300.0 kPa
    Ac
    10.91 cm²
  • σ′3c
    400.0 kPa
    Ac
    10.84 cm²

Shear readingsStep #4

Specimen 1 · σ3 400 kPa
#δ (mm)P (N)Δu (kPa)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Charts