Theory · RET-03 · Retaining
Retaining Wall Stability
How the backfill's thrust and the wall's weight balance in the sliding, overturning and bearing checks of a retaining wall.
Pick the wall type (gravity, semi-gravity or cantilever) and enter its section, the backfill and the foundation soil to get the thrust by Rankine or Coulomb and the checks against sliding, overturning and bearing, with the base pressures and the middle third.
Wall types
A gravity wall resists by its weight, of concrete or masonry, with a wide section; a semi-gravity wall, slimmer, has light reinforcement; a cantilever wall (L or inverted T) is reinforced concrete and uses the weight of the soil over its heel. The page uses one section for all three: a base with a toe and a heel and a stem whose front may batter back.
Thrust
By Rankine, the thrust acts on the vertical plane through the heel's end, parallel to the ground, and the soil between that plane and the wall counts as part of it. By Coulomb, it acts on the plane from the base's back corner to the stem's top, inclined θ from the vertical, at δ to its normal; it is the natural theory for gravity walls, where that plane is nearly the wall's back.
With water, the base takes a triangular uplift, from the water pressure at the heel to none at the drained toe.
Sliding
Overturning
Base pressures and bearing capacity
On this page
- The required safety factors are the usual ones (Das): 1.5 against sliding, 2.0 against overturning and 3.0 against bearing failure. The Brazilian page takes the same numbers from NBR 11682 and NBR 6122.
- The backfill is cohesionless; the surcharge enters the thrust, but its weight over the heel doesn't count towards stability.
- The soil over the toe, in front, isn't among the weights; the passive in front counts only against sliding, and only if included, at the share picked.
- By Coulomb, the thrust is spread linearly up the plane's height, as in ½ Ka γ H², and the water acts on the plane's vertical projection.
- The key, under the stem, extends the passive down to its foot; without the passive included it doesn't change the result.
- Global stability, along a surface passing under the wall, isn't checked here: use the slope stability app.
The 3D is an illustration of the wall as built, a stretch of it along its axis, with the backfill over the heel, the soil in front and the water; the section and the drawing carry the forces and the dimensions.
Limitations
- These are external checks: the structural design of the stem and base (bending, shear, reinforcement) isn't done.
- The thrust is the active one: the wall must be able to move enough to mobilize it; a restrained wall takes the at-rest thrust, which is larger.
- A poorly drained backfill builds up water and can double the thrust: drains and weep holes are part of the design.
References
- Coduto, D. P., Kitch, W. A. and Yeung, M. R. Foundation Design: Principles and Practices, 3rd ed. Pearson, 2016.
- Das, B. M. Principles of Foundation Engineering. Cengage Learning.
- Meyerhof, G. G. The bearing capacity of foundations under eccentric and inclined loads. Proc. 3rd International Conference on Soil Mechanics and Foundation Engineering, Zurich, vol. 1, 440–445, 1953.
- Terzaghi, K., Peck, R. B. and Mesri, G. Soil Mechanics in Engineering Practice, 3rd ed. Wiley, 1996.