# Plate Load Test

> Get the allowable bearing pressure from a plate load test's stress–settlement curve, with Van der Veen failure, modulus E, subgrade reaction and footing settlement.

Interactive app: https://app.geofluxo.com/en-US/apps/plate-load

Enter the plate and the test's load stages, each with its stress and settled settlement, to get the failure stress by Van der Veen, the allowable bearing pressure by US practice with ASTM D1194 (the footing's failure and its 1 in settlement) or by Brazil's NBR 6122 (failure and the plate's 10 and 25 mm settlements), the soil's elastic modulus and modulus of subgrade reaction, and a footing's settlement by the scale effect.

## Theory

How a plate load test gives a shallow foundation's allowable bearing pressure, the soil's modulus and a footing's settlement.

### The test

A rigid steel plate, commonly 0.30 to 0.76 m (12 to 30 in) across, is bedded at the bottom of a pit at footing level and loaded by a hydraulic jack reacting against a kentledge or anchors. The load goes up in stages, each held until the settlement levels off, read on dial gauges supported outside the plate's zone of influence. The test goes on to failure, to an excessive settlement or to at least twice the expected allowable pressure, and the plate is then unloaded in stages.

The stress–settlement curve, settlement downward, is the test's result. In soils failing in general shear it bends over to a clear plateau; in loose or soft soils it keeps bending gradually, with no clear failure.

### Failure stress

Where the test doesn't take the soil to failure, failure is estimated by fitting an exponential to the loading curve (Van der Veen, 1953):

$$
\sigma = \sigma_f \left(1 - e^{-a\,s}\right) \quad\Longleftrightarrow\quad -\ln\!\left(1 - \frac{\sigma}{\sigma_f}\right) = a\,s
$$

σ<sub>f</sub>: failure stress · a: the curve's shape coefficient (1/mm) · s: settlement

For each trial σ<sub>f</sub> above the largest stress applied, the points −ln(1 − σ/σ<sub>f</sub>) against s make a line through the origin; σ<sub>f</sub> is the one that makes it straightest (the largest R²). If the curve hardly bends, the best σ<sub>f</sub> lies far beyond the test and the fit isn't used: σ<sub>f</sub> becomes the largest stress applied, a lower bound on failure.

### Allowable bearing pressure

Under Brazil's NBR 6122, the allowable pressure meets failure, with a factor of safety of 2.0 for pressures from load tests, and settlement, by the Boston Building Code's criterion, still used to read plate tests:

$$
\sigma_{all} = \min\left(\frac{\sigma_f}{FS},\; \sigma_{10},\; \frac{\sigma_{25}}{2}\right)
$$

σ<sub>10</sub>, σ<sub>25</sub>: the stresses that settle the plate 10 and 25 mm (0.4 and 1 in)

Under ASTM D1194, US practice (Das) reads the criterion on the footing: its failure, with a factor of safety of 3, and the pressure that settles it 1 in (25.4 mm), by the scale effect. In clay the footing fails at the plate's stress; in sand at a larger one, in proportion to its width:

$$
\sigma_{all} = \min\left(\frac{q_{u,B}}{FS},\; \sigma_{s_B = 1\,in}\right) \qquad q_{u,B} = \sigma_f \;(\text{clay}) \quad q_{u,B} = \sigma_f \frac{B}{B_p} \;(\text{sand})
$$

With no footing width, the plate: q<sub>u,B</sub> = σ<sub>f</sub> and the plate's own 1 in settlement

Either way, σ<sub>all</sub> never exceeds the largest stress applied in the test. By the NBR criterion it holds for the plate: a larger footing under the same pressure settles more (see Scale effect).

### Modulus and subgrade reaction

Under the allowable pressure, the plate's settlement gives the soil's elastic modulus, by Boussinesq's solution for a rigid plate on an elastic half-space, and its modulus of subgrade reaction (Winkler's), used for beams and mats on elastic foundations:

$$
E = \frac{(1 - \nu^2)\, I\, \sigma\, B_p}{s} \qquad k_p = \frac{\sigma}{s}
$$

I: the rigid plate's influence factor · B<sub>p</sub>: the plate's diameter or side · ν: the soil's Poisson's ratio

| Rigid plate | I |
| --- | --- |
| Circular | π/4 ≈ 0.79 |
| Square | 0.82 |

| Soil | ν |
| --- | --- |
| Saturated clay (undrained) | 0.45 to 0.50 |
| Unsaturated clay | 0.30 to 0.40 |
| Silt | 0.30 to 0.35 |
| Sand | 0.25 to 0.35 |

### Scale effect

A footing of width B stresses the ground deeper than the plate, and under the same pressure it settles more. Terzaghi and Peck (1948) relate the two:

$$
\text{Sand: } \frac{s_B}{s_p} = \left(\frac{2B}{B + B_p}\right)^2 \qquad \text{Clay: } \frac{s_B}{s_p} = \frac{B}{B_p}
$$

s<sub>B</sub>, s<sub>p</sub>: the footing's and the plate's settlement under the same pressure · the footing's modulus of subgrade reaction is k<sub>s</sub> = k<sub>p</sub> · s<sub>p</sub>/s<sub>B</sub>

In sand the ratio tends to 4 for very wide footings, as sand stiffens with confinement; in clay, whose stiffness hardly changes with depth, it grows in proportion to the width.

### On this page

- The test is the same under ASTM D1194 (withdrawn in 2003 but still the US reference) and Brazil's NBR 6489; the standard picked in step 1 changes how the curve is read: ASTM, with FS = 3, by default here; NBR, with FS = 2, by default on the Portuguese page. Switching standard switches FS, unless one was typed.
- Each stage is the stress on the plate and the settlement once it has levelled off, from the start of the test; a spreadsheet table can be pasted, and Enter moves down a row. Stages after the largest stress are the unloading, which only goes into the chart and the recovered settlement.
- σ<sub>10</sub>, σ<sub>25</sub> and the settlement under σ<sub>all</sub> are interpolated between stages; where they lie past the last one, they are read off Van der Veen's fit and marked *.
- E and k<sub>p</sub> are secant values, from the origin to the curve's point under σ<sub>all</sub>.
- The footing's settlement is the plate's under σ<sub>all</sub> times Terzaghi and Peck's ratio; the dashed curve is the plate's with its settlements scaled so.

The 3D is an illustration of a usual setup for the test, the reaction from blocks of kentledge on a beam; the reaction isn't designed here.

### Limitations

- The plate stresses the soil only to about twice its width. A weaker layer below that depth won't show in the test but may govern the footings' settlement: the test needs borings beside it.
- The test is quick: in saturated clays it measures the undrained response and leaves out consolidation.
- Terzaghi and Peck's scale effect is empirical and holds for uniform soils; on collapsible soils the test should be repeated with the soil flooded.

## References

- ASTM International. ASTM D1194-94, Standard Test Method for Bearing Capacity of Soil for Static Load and Spread Footings (withdrawn 2003). West Conshohocken, PA.
- ABNT. NBR 6489: Solo – Prova de carga estática em fundação direta. Rio de Janeiro, 2019.
- Cintra, J. C. A., Aoki, N. and Albiero, J. H. Fundações diretas: projeto geotécnico. Oficina de Textos, São Paulo, 2011.
- Das, B. M. Principles of Foundation Engineering. Cengage Learning, Boston.
- Terzaghi, K. and Peck, R. B. Soil Mechanics in Engineering Practice. Wiley, New York, 1948.
- Van der Veen, C. The bearing capacity of a pile. Proc. 3rd International Conference on Soil Mechanics and Foundation Engineering, Zurich, vol. 2, 84–90, 1953.