# Pile Bearing Capacity from SPT

> Estimate the bearing capacity and allowable load of a pile from an SPT boring by the Aoki-Velloso and Décourt-Quaresma methods. Online pile capacity calculator.

Interactive app: https://app.geofluxo.com/en-US/apps/piles

Enter the pile — type, section, size and length —, the soil layers and the N values of an SPT boring to estimate the bearing capacity and allowable load by Aoki-Velloso's and Décourt-Quaresma's methods.

## Theory

How Aoki-Velloso's and Décourt-Quaresma's semi-empirical methods estimate a pile's bearing capacity from the N values of an SPT boring, and how the allowable load follows.

### Bearing capacity

An axially loaded pile passes its load to the soil through friction along its shaft and the resistance under its tip. At failure, its capacity is the sum of the two.

$$
R = R_p + R_l = r_p A_p + U \sum r_l\, \Delta l
$$

r<sub>p</sub>: unit tip resistance · A<sub>p</sub>: tip area · U: shaft perimeter · r<sub>l</sub>: unit shaft friction in each stretch of length Δl

In Brazil, r<sub>p</sub> and r<sub>l</sub> usually come from correlations with the SPT's N, a test run on almost every site. The methods are semi-empirical: calibrated on load tests of certain pile types and soils, they should be used within that context.

### Aoki-Velloso

Aoki and Velloso (1975) started from the cone penetration test (CPT), taking the pile's tip as a full-scale cone. The cone's tip resistance relates to N through K, and its sleeve friction to its tip resistance through α; the factors F<sub>1</sub> and F<sub>2</sub> account for the difference in scale and the way the pile is built.

$$
r_p = \frac{K N_p}{F_1}\qquad r_l = \frac{\alpha K N_l}{F_2}
$$

N<sub>p</sub>: N at the tip's depth · N<sub>l</sub>: N of each stretch of the shaft

| Soil | K (MPa) | α (%) |
| --- | --- | --- |
| Sand | 1.00 | 1.4 |
| Silty sand | 0.80 | 2.0 |
| Silty clayey sand | 0.70 | 2.4 |
| Clayey sand | 0.60 | 3.0 |
| Clayey silty sand | 0.50 | 2.8 |
| Silt | 0.40 | 3.0 |
| Sandy silt | 0.55 | 2.2 |
| Sandy clayey silt | 0.45 | 2.8 |
| Clayey silt | 0.23 | 3.4 |
| Clayey sandy silt | 0.25 | 3.0 |
| Clay | 0.20 | 6.0 |
| Sandy clay | 0.35 | 2.4 |
| Sandy silty clay | 0.30 | 2.8 |
| Silty clay | 0.22 | 4.0 |
| Silty sandy clay | 0.33 | 3.0 |

| Pile | F<sub>1</sub> | F<sub>2</sub> |
| --- | --- | --- |
| Franki | 2.50 | 5.00 |
| Precast concrete | 1 + D/0.80 | 2F<sub>1</sub> |
| Steel | 1.75 | 3.50 |
| Bored | 3.00 | 6.00 |
| CFA and root | 2.00 | 4.00 |

### Décourt-Quaresma

Décourt and Quaresma (1978) related N directly to the resistances of precast concrete piles. At the tip, N<sub>p</sub> is the mean of the N at the tip and those just above and below; along the shaft, N<sub>l</sub> is the mean along it, without those used at the tip, each N between 3 and 50.

$$
r_p = \alpha\, C\, N_p\qquad r_l = 10\, \beta \left(\frac{N_l}{3} + 1\right) \ \text{(kPa)}
$$

C: coefficient of the soil at the tip · α and β: factors for the pile type (Décourt, 1996)

| Soil at the tip | C (kPa) |
| --- | --- |
| Clays | 120 |
| Clayey silts (residual soil) | 200 |
| Sandy silts (residual soil) | 250 |
| Sands | 400 |

| Pile | α clay / silt / sand | β clay / silt / sand |
| --- | --- | --- |
| Driven | 1.00 / 1.00 / 1.00 | 1.00 / 1.00 / 1.00 |
| Bored | 0.85 / 0.60 / 0.50 | 0.80 / 0.65 / 0.50 |
| CFA | 0.30 / 0.30 / 0.30 | 1.00 / 1.00 / 1.00 |
| Root | 0.85 / 0.60 / 0.50 | 1.50 / 1.50 / 1.50 |

### Allowable load

$$
P_a = \frac{R}{\mathrm{FS}}
$$

NBR 6122 asks for FS = 2 when the capacity comes from semi-empirical methods, without load tests

- In bored piles, NBR 6122 holds the tip's share to 20% of the allowable load, as the base is hard to clean: the shaft must carry the rest.
- The two methods often differ, sometimes widely; comparing them, and with load tests from the region, gives a measure of the uncertainty.
- The pile's allowable load also depends on its settlement and the structural strength of its shaft, which this app doesn't check.

### On this page

- Each N stands for the stretch between its test and the one above (the first from the surface); the pile's head is at the surface, and its tip takes the N of the stretch it's in.
- Aoki-Velloso: r<sub>p</sub> = K·N<sub>p</sub>/F<sub>1</sub> and r<sub>l</sub> = α·K·N/F<sub>2</sub>, with K and α from each stretch's soil (Aoki and Velloso, 1975) and F<sub>1</sub> and F<sub>2</sub> from the pile type (Cintra and Aoki, 2010).
- N above 50 is taken as 50. The allowable load is R/FS (NBR 6122 asks for FS = 2 with semi-empirical methods); in bored piles, the tip carries at most 20% of it.
- The length chart puts the tip at each test's depth, with the same pile and profile.
- The 3D is an illustration: the bars over the head of cast-in-place piles (φ16) and the Franki pile's base show the work as built but aren't designed here, and the base isn't counted in the capacity.
- From the top down, each layer with its soil in Aoki and Velloso's classification and the depth of its bottom. They must reach the tip.
- One N per test, usually every meter. They must reach the tip; the one just below it counts in Décourt-Quaresma's tip.
- P<sub>a</sub> = R/FS; NBR 6122 asks for FS = 2 with semi-empirical methods. Allowable loads below P are marked.

## References

- Aoki, N.; Velloso, D. A. An approximate method to estimate the bearing capacity of piles. In: Panamerican Conference on Soil Mechanics and Foundation Engineering, 5., Buenos Aires, 1975. v. 1, p. 367–376.
- Décourt, L.; Quaresma, A. R. Capacidade de carga de estacas a partir de valores de SPT. In: Congresso Brasileiro de Mecânica dos Solos e Engenharia de Fundações, 6., Rio de Janeiro, 1978. v. 1, p. 45–53.
- Décourt, L. et al. Análise e projeto de fundações profundas. In: Hachich, W. et al. (ed.). Fundações: teoria e prática. São Paulo: Pini, 1996.
- Cintra, J. C. A.; Aoki, N. Fundações por estacas: projeto geotécnico. São Paulo: Oficina de Textos, 2010.
- ABNT. NBR 6122: Projeto e execução de fundações. Rio de Janeiro, 2019.