Theory · TST-20 · Testing
Static Pile Load Test
How a static load test gives a pile's failure load and allowable load, by Davisson's and NBR 6122's offset limits and by the Van der Veen, Chin and Décourt extrapolations.
Enter the pile (shape, diameter, length and the material's modulus) and the static load test's stages, each with its load and settled settlement, to get the failure load by Davisson's offset limit or Brazil's NBR 6122 (D/30), the Van der Veen, Chin and Décourt extrapolations, the allowable load and the settlement under it, and whether the test proves the working load, per ASTM D1143.
The test
In a static axial compressive load test (ASTM D1143; NBR 16903 in Brazil), a hydraulic jack on the pile head pushes it down against a reaction system: a beam tied to reaction piles or anchors, or a kentledge. The load is raised in equal increments and the head's settlement is read on dial gauges or displacement transducers mounted on reference beams supported clear of the pile and the reaction.
In a maintained load test each increment is held until the settlement levels off; in a quick test, for a short fixed time. The test goes on to failure or at least to twice the design load, and the pile is then unloaded in steps. The result is the load–settlement curve, settlement plotted downward.
Offset limit
A pile rarely plunges under constant load, a clear failure. So failure is defined at a settlement: where the curve crosses the line of the pile's elastic shortening offset by a set amount. By Davisson (1972), the usual criterion in US practice:
Brazil's NBR 6122 offsets the line by D/30, a larger settlement:
Qu is the load at which the curve reaches that line. If the test stopped short of it, the curve may be extrapolated: here, by Van der Veen's fit.
Van der Veen extrapolation
Van der Veen (1953) fits the loading curve with an exponential that levels off at Qu:
For each trial Qu above the largest load, the points −ln(1 − Q/Qu) against s fall on a line through the origin; Qu is the one that makes it straightest (the highest R²). The extrapolation is only as good as the test: if the largest load is below about 2/3 of failure, the curve hasn't bent enough to fit.
Chin and Décourt methods
Chin (1970) takes the curve to be a hyperbola, which plots as a straight line of s/Q against s; the inverse of its slope is the asymptotic load:
Décourt (1999) plots the head's stiffness, Q/s, against load. It drops as the pile nears failure, the load of zero stiffness, where the line through the last points meets the axis:
Both give the load at very large settlement and so usually lie above the offset limit; Chin's, typically 20 to 40% above (Fellenius). Use them to judge the curve and the extrapolation, not for design.
Allowable load
In allowable stress design, FS = 2.0 is customary when the capacity comes from a static load test. Brazil's NBR 6122 also takes 2.0, lowered to 1.6 when enough static load tests are run at the design stage. The working load P must not exceed Qall, and a proof test should reach at least 2P.
On this page
- The test is the same under ASTM D1143 and NBR 16903; the standard picked in step 1 sets the offset limit: Davisson's, the default on this page and in Spanish, or NBR 6122's D/30, the default in Portuguese. FS = 2 under both.
- Each stage is the load on the head and the settled settlement at its end, from the start of the test; a spreadsheet table can be pasted, and Enter moves down a row. The stages after the largest load are the unloading, which only enters the chart and the residual and recovered settlements.
- The area is the full section's (πD²/4 or D²), and the elastic shortening takes the whole load down the whole shaft, as the criteria do. E is about 3,000 to 4,400 ksi (21,000 to 30,000 MPa) for concrete piles and 29,000 ksi (200,000 MPa) for steel.
- Qu is interpolated between the stages where the curve crosses the criterion's line; when the crossing lies past the last stage it is read off Van der Veen's fit and marked *. With neither, Qu is the largest load applied, a lower bound.
- Chin's and Décourt's lines are fitted to the stages from half the largest load up (the last three at least); on the chart, the points left out are hollow.
The 3D is an illustration of a usual setup for the test: the reaction beam tied down to two reaction piles, at least three diameters away, and the reference beams resting clear of them; the reaction system isn't designed here.
Limitations
- The test measures the head: without gauges along the shaft, it doesn't split shaft friction from toe resistance.
- In clay, a quick test measures the undrained response; the long-term settlement of a pile group doesn't show in a test on a single pile.
- Reaction piles too close (under about three diameters) change the result; ASTM D1143 and NBR 16903 set minimum clearances.
- Davisson's criterion was calibrated on small-diameter driven piles and tends to be conservative for large-diameter drilled shafts, which need more movement to mobilize the toe.
References
- ASTM International. ASTM D1143/D1143M-20, Standard Test Methods for Deep Foundation Elements Under Static Axial Compressive Load. West Conshohocken, PA, 2020.
- ABNT. NBR 16903, Solo – Prova de carga estática em fundação profunda. Rio de Janeiro, 2020.
- ABNT. NBR 6122, Projeto e execução de fundações. Rio de Janeiro, 2019.
- Chin, F. K. (1970). Estimation of the ultimate load of piles from tests not carried to failure. Proc. 2nd Southeast Asian Conference on Soil Engineering, Singapore, 81–92.
- Davisson, M. T. (1972). High capacity piles. Proc. Soil Mechanics Lecture Series on Innovations in Foundation Construction, ASCE Illinois Section, Chicago, 81–112.
- Décourt, L. (1999). Behavior of foundations under working load conditions. Proc. 11th Pan-American Conference on Soil Mechanics and Geotechnical Engineering, Foz do Iguaçu, 4, 453–488.
- Fellenius, B. H. (2017). Basics of Foundation Design. Revised electronic edition, Calgary.
- Van der Veen, C. (1953). The bearing capacity of a pile. Proc. 3rd International Conference on Soil Mechanics and Foundation Engineering, Zurich, 2, 84–90.