Theory: Permeability
How constant and falling head tests measure a soil's hydraulic conductivity by Darcy's law, and why it's corrected to 20 °C.
Darcy's law
In laminar flow, the flow through a saturated soil is proportional to the hydraulic gradient:
Constant head
For permeable soils, sands and gravels. Water passes through the specimen under a fixed difference of level, and the volume out in a time is measured. Readings under different gradients draw the Darcy line: if it passes through the origin, the flow is laminar and the law holds.
Falling head
For soils of low permeability, silts and clays, where the volume through would be too small to measure. Water falls in a thin standpipe joined to the specimen, and the time for its level to drop from h1 to h2 is measured.
Correction to 20 °C
The hydraulic conductivity depends on the water's viscosity, which falls as it warms. To compare tests, it's taken to the reference temperature of 20 °C:
| Soil | k (cm/s) |
|---|---|
| Gravel | > 10−1 |
| Sand | 10−3 to 10−1 |
| Fine sand, silty sand | 10−5 to 10−3 |
| Silt, sandy clay | 10−7 to 10−5 |
| Clay | < 10−7 |
On this page
- Constant head per ASTM D2434 and falling head per ASTM D5856; the Portuguese page follows ABNT NBR 13292 and NBR 14545. The calculations are the same.
- Lengths in cm, volumes in cm³, times in s and k in cm/s, as labs report them; the result in m/s too, the unit of the seepage and drawdown apps, which can take it through links.
- The test's k is the mean of the ticked readings' k20; untick one to leave it out. At constant head, the slope of the Darcy line through the origin gives another estimate, from all the readings together.
The 3D is an illustration of the permeameter with the specimen and the standpipe at their sizes; the reservoir and the measuring cylinder are generic.
Limitations
- The specimen must be saturated; trapped air lowers the measured k a great deal.
- At high gradients the flow stops being laminar and the Darcy line bends; use the readings on its straight part.
- A laboratory k is that of a small sample; in the field, layering, fissures and anisotropy can change it by orders of magnitude.
References
- ASTM D2434. Standard Test Method for Permeability of Granular Soils (Constant Head). West Conshohocken: ASTM International.
- ASTM D5856. Standard Test Method for Measurement of Hydraulic Conductivity of Porous Material Using a Rigid-Wall, Compaction-Mold Permeameter. West Conshohocken: ASTM International.
- Rumble, J. R. (Ed.). CRC Handbook of Chemistry and Physics. Boca Raton: CRC Press.
- Das, B. M.; Sobhan, K. Principles of Geotechnical Engineering. 9th ed. Boston: Cengage, 2018.