Skip to content
Footing Design

Theory · FND-06 · Foundations

Isolated Footing Design

How an isolated footing is designed: its plan by the soil, with eccentric loads and settlement, and its height and reinforcement by the concrete, as NBR 6122 and NBR 6118 ask.

Enter the column — its section, load and moments —, the footing's depth and the soil to design a rigid isolated footing: the plan with equal overhangs, checked for bearing, the area in compression and settlement, then its height, reinforcement and the concrete and steel it takes, seen in 3D with the stress under its base.

A plan with equal overhangs

An isolated footing carries a column's load into the soil. Its plan is picked so the soil carries it safely and it settles little; with equal overhangs past the column's faces, the bending moments in both directions come out alike and the reinforcement economical.

Bx−ax=By−ayB_x - a_x = B_y - a_y
BxBy≥N+PσadmB_x B_y \ge \frac{N + P}{\sigma_{\mathrm{adm}}}
a: the column's sides · B: the footing's · P: the weight of the footing and the soil over it

Eccentric loads

Moments move the resultant off the centre: ex = Mx/N, ey = My/N. While it stays in the kern, the whole base is in compression and the stress varies linearly; past it, part of the base lifts off, as the soil takes no tension.

σ=NBxBy(1±6exBx±6eyBy)\sigma = \frac{N}{B_x B_y}\left(1 \pm \frac{6 e_x}{B_x} \pm \frac{6 e_y}{B_y}\right)
6∣ex∣Bx+6∣ey∣By≤1\frac{6|e_x|}{B_x} + \frac{6|e_y|}{B_y} \le 1
The whole base in compression: the resultant in the kern's diamond

Past the kern, the stress is a plane over the area still in contact, found so that it balances the load and both moments. NBR 6122 asks for at least ⅔ of the base in compression.

For bearing capacity, Meyerhof replaces the base by an effective area centred on the resultant, B′ × L′ = (Bx − 2ex)(By − 2ey), loaded uniformly. With a given allowable stress, NBR 6122 lets the edge stress reach 1.3σadm.

Settlement

s=qnet B 1−ν2Es Is = q_{\mathrm{net}}\, B\, \frac{1 - \nu^2}{E_s}\, I
qnet: the mean stress less the geostatic one at the base · B: the shorter side · I: a rigid footing's influence factor
L/B11.523510
I (rigid)0.821.061.201.421.702.10

Rigid footings

NBR 6118 calls a footing rigid when its height is at least a third of its overhang. The load then goes down to the base in compressed struts, punching doesn't occur, and only the concrete's diagonal compression by the column needs checking.

h≥B−a3h \ge \frac{B - a}{3}
τSd=FSdu0 d≤τRd2=0.27(1−fck250)fcd\tau_{Sd} = \frac{F_{Sd}}{u_0\, d} \le \tau_{Rd2} = 0.27\left(1 - \frac{f_{ck}}{250}\right) f_{cd}
u0: the column's perimeter · d: the effective depth · FSd = 1.4N

Reinforcement by CEB-70

CEB-70 takes the moment at a reference section 0.15 of the column's side inside its face, from the soil's reaction on the overhang past it. The effective depth taken is at most 1.5 times that overhang.

As=1.4 Mk0.85 d fyd≥0.15% AcA_s = \frac{1.4\, M_k}{0.85\, d\, f_{yd}} \ge 0.15\%\, A_c
Ac: the footing's section at the reference section · fyd = fyk/1.15

The bars are spread over the whole side, 10 to 20 cm apart, with the smallest diameter that keeps to that spacing.

On this page

  • A rigid footing (NBR 6118) with a rectangular base, faces sloping up to a 2.5 cm collar around the column and an edge h0 ≥ h/3 and ≥ 20 cm. The plan is sized with equal overhangs, in 5 cm steps, from 0.60 m (NBR 6122).
  • The footing's weight (25 kN/m³) and the soil's over it add to the load on the base; buoyancy and side friction are left out.
  • Immediate settlement of a rigid footing on a homogeneous elastic half-space, with Bowles's influence factor; consolidation of clays isn't included.
  • Reinforcement by the CEB-70 method, at the section 0.15 of the column inside its face, from the soil's reaction to the column's load; CA-50 bars hooked up at both ends, to the edge's top less the cover. Diagonal compression at the column's face by NBR 6118 (τRd2); the anchorage of the column's bars isn't checked.
  • The 3D is an illustration: the pit with 40 cm of working space, the backfill, the topsoil, the spacers and the column's starter bars and ties (φ12.5 and φ5) show the work as built but aren't designed here. The 2D drawing carries the dimensions, the reinforcement and the stresses.
  • Characteristic loads, at the footing's top. Mx moves the resultant along x (ex = Mx/N), My along y.
  • The smallest plan with equal overhangs the soil carries. The height comes from rigidity and diagonal compression.
  • The plan entered is checked; the height still comes from rigidity and diagonal compression.
  • qu by the method picked, on the effective area; NBR 6122 asks for FS = 3 with theoretical methods. Leave the water table blank when it's deep.
  • σadm, from tests or correlations (with the SPT, say), over the whole base. Leave the water table blank when it's deep.
  • d′ runs from the base to the bars' centre. γf = γc = 1.4 and γs = 1.15.

References

  1. ABNT. NBR 6122: Projeto e execução de fundações. Rio de Janeiro, 2019.
  2. ABNT. NBR 6118: Projeto de estruturas de concreto. Rio de Janeiro, 2023.
  3. Comité Européen du Béton. Recommandations particulières au calcul et à l'exécution des semelles de fondation. Bulletin d'Information n. 73, 1970.
  4. Meyerhof, G. G. The bearing capacity of foundations under eccentric and inclined loads. Proc. 3rd ICSMFE, v. 1, p. 440–445, 1953.
  5. Bowles, J. E. Foundation Analysis and Design. 5th ed. New York: McGraw-Hill, 1996.
  6. Velloso, D. A.; Lopes, F. R. Fundações. New ed. São Paulo: Oficina de Textos, 2010.