# Field Permeability Tests

> Get hydraulic conductivity in boreholes from constant head, falling or rising head (Hvorslev, Bouwer–Rice) and packer (Lugeon, Houlsby) tests, per USBR and ASTM D4044.

Interactive app: https://app.geofluxo.com/en-US/apps/field-permeability

Pick the test — constant head, variable head (falling or rising head, a slug test) or a packer (Lugeon) test —, describe the borehole and the water table and enter the field readings, to get the hydraulic conductivity by Hvorslev's shape factor or by Bouwer and Rice or, in rock, the lugeons of each stage and Houlsby's flow behavior, as in the USBR Earth Manual and ASTM D4044.

## Theory

How borehole tests — constant head, variable head and Lugeon — measure hydraulic conductivity in the field, by Hvorslev's shape factor, by Bouwer and Rice and by Houlsby's reading.

### Borehole permeability tests

A lab test measures a small sample; in the field, layering, fissures and the soil's fabric can change the hydraulic conductivity by orders of magnitude. In a borehole test, water enters the ground through a known opening — the end of the casing, or an open length below it — under a head H, and the flow Q it takes gives k through the opening's shape:

$$
k = \frac{Q}{F\,H}
$$

Q: flow · H: head over the rest level · F: the opening's shape factor, a length (Hvorslev, 1951)

H runs from the water in the hole to the rest level: the water table, when the test is below it; above the water table, the test section itself — the bottom of an open end, the middle of an open section —, from which the water drains into the unsaturated ground (USBR Earth Manual).

### Shape factor

For a uniform, isotropic soil Hvorslev gave F for each shape of opening. The page uses the two most common:

$$
F_{\text{end}} = 2.75\,D \qquad F_{\text{section}} = \frac{2\pi L}{\ln\!\left[\frac{L}{D} + \sqrt{1 + \left(\frac{L}{D}\right)^2}\right]}
$$

D: hole diameter · L: open section length. For L much longer than D, the log tends to ln(2L/D) = ln(L/r).

### Constant head

The water is kept at one level in the hole — usually the top of the casing — and the volume it takes to hold it there is measured over each interval, every minute at first. The flow falls as the ground around saturates, until it steadies; the steady flow gives k. It suits soils of moderate to high permeability.

$$
Q = \frac{V_i}{t_i - t_{i-1}} \qquad k = \frac{Q_{\text{steady}}}{F\,H}
$$

V<sub>i</sub>: water put in over interval i · Q<sub>steady</sub>: the mean of the last three intervals

### Variable head (Hvorslev)

The water in the pipe is raised at once (falling head) or bailed or displaced down (rising head, as in a slug test), and its depth is read over time. Its displacement y from rest decays exponentially: on a plot of log y against t the readings fall on a line, whose slope gives the basic time lag T<sub>0</sub>, when y is down to 37% (e<sup>−1</sup>) of its start.

$$
k = \frac{A}{F\,(t_2 - t_1)}\,\ln\frac{y_1}{y_2} = \frac{A}{F\,T_0} \qquad A = \frac{\pi d_c^2}{4}
$$

A: inside area of the pipe the water moves in · d<sub>c</sub>: its diameter · T<sub>0</sub> = −1 / slope of ln y against t

Early readings off the line (inertia, the pipe filling) and late ones near rest can be left out of the fit. It suits low-permeability soils, where a constant head test's flow would be too small to measure.

### Bouwer and Rice

For a well or piezometer screened below the water table in an unconfined aquifer, Bouwer and Rice (1976) replaced the shape factor by an effective radius R<sub>e</sub>, as far as the disturbance reaches, taken from electrical analog models:

$$
K = \frac{r_c^2 \ln(R_e / r_w)}{2 L_e}\,\frac{1}{t}\ln\frac{y_0}{y_t}
$$

r<sub>c</sub>: casing radius · r<sub>w</sub>: borehole radius (with the filter pack) · L<sub>e</sub>: screen length (the section)

$$
\ln\frac{R_e}{r_w} = \left[\frac{1.1}{\ln(L_w/r_w)} + \frac{A + B\ln\left[(H - L_w)/r_w\right]}{L_e/r_w}\right]^{-1} \qquad \ln\frac{R_e}{r_w} = \left[\frac{1.1}{\ln(L_w/r_w)} + \frac{C}{L_e/r_w}\right]^{-1}
$$

L<sub>w</sub>: water table to the bottom of the well · H: the aquifer's saturated thickness, water table to base. The first for a partially penetrating well (ln[(H − L<sub>w</sub>)/r<sub>w</sub>] at most 6); the second for a well down to the base.

A, B and C come from Bouwer and Rice's curves against L<sub>e</sub>/r<sub>w</sub>; the page works them out by Yang and Yeh's (2004) fourth-degree fits in x = log₁₀(L<sub>e</sub>/r<sub>w</sub>), valid from 4 to 2000.

### Packer (Lugeon) test

In rock, a length of hole is sealed off with packers and water is pumped in at rising then falling pressures — typically five stages, a–b–c–b–a —, reading each one's steady flow. One lugeon is a flow of 1 liter a minute per meter of section under 1 MPa:

$$
Lu = \frac{Q}{L}\cdot\frac{1000}{P} \qquad P = p_{\text{gauge}} + \gamma_w\,(h_g + z)
$$

Q in L/min · L in m · P: effective pressure at the section, kPa · p<sub>gauge</sub>: the gauge reading · h<sub>g</sub>: gauge height above the ground · z: depth to the middle of the section, or to the water table where it's above it. Pipe friction losses aren't taken off.

Houlsby (1976) reads the stages' lugeons together to tell how the water moved in the joints and which value to report:

| Behavior | Lu over the stages | Value reported |
| --- | --- | --- |
| Laminar | about equal | the mean |
| Turbulent | lowest at the peak pressure | the peak's |
| Dilation | highest at the peak pressure | the lowest |
| Wash-out | rising | the last (highest) |
| Void filling | falling | the last (lowest) |

An equivalent k follows from the reported Lu through the section's shape factor, with H = 1 MPa / γ<sub>w</sub>: for 3 m sections in NX holes, 1 Lu ≈ 1 to 1.3 × 10<sup>−7</sup> m/s.

| Lu | Rock mass |
| --- | --- |
| < 1 | very low permeability, tight joints |
| 1 to 5 | low permeability |
| 5 to 15 | moderate permeability |
| 15 to 50 | permeable, open joints |
| 50 to 100 | highly permeable |
| > 100 | very open joints |

### Typical values

| Soil | k (m/s) |
| --- | --- |
| Gravel | > 10<sup>−3</sup> |
| Sand | 10<sup>−5</sup> to 10<sup>−3</sup> |
| Fine sand, silty sand | 10<sup>−7</sup> to 10<sup>−5</sup> |
| Silt, sandy clay | 10<sup>−9</sup> to 10<sup>−7</sup> |
| Clay | < 10<sup>−9</sup> |

### On this page

- Follows the USBR Earth Manual and ASTM D4044; the Portuguese page follows ABGE's Bulletins 04 (soils) and 02 (packer tests). The calculations are the same.
- Depths are taken down from the ground; the level kept in the hole is negative above the ground, at the top of the casing. With the water table left blank, the test is taken to be above it.
- Constant head: each interval's flow is its volume over its length; the steady flow, the mean of the last three, with a warning while they still differ by more than 10%.
- Variable head: the line is fitted by least squares of ln y on t, over the ticked readings only. Bouwer and Rice's k shows when the section is open and wholly below the water table; the analysis picked gives the k passed on to other apps.
- Lugeon: the peak stage is the one of highest P; the lugeons are taken as laminar within 20% of their mean. The pipe's head is the gauge's: take friction losses off first where they matter.
- k is in m/s, the unit of the seepage and drawdown apps, which can take it through links. Metric or imperial units, as picked; a decimal comma or point is accepted.

The 3D is an illustration of the test, the hole drawn wider in deep ones so it shows, and the equipment on the surface generic: a drum and hose for the constant head, the casing for the falling head, and the packer, gauge and pump for the Lugeon test.

### Limitations

- The shape factors assume a uniform, isotropic soil; in an anisotropic one a long section measures mostly the horizontal k and an open end more of the vertical.
- Above the water table the soil isn't saturated and k is approximate, usually lower than the saturated value.
- Walls smeared or clogged by drilling and mud lower the k measured; clean the hole well before testing.
- Bouwer and Rice hold for unconfined aquifers; in confined ones they give a fair estimate if the screen is clear of the confining layer.
- In a Lugeon test, too high a pressure can open joints (hydraulic fracturing); keep it below what the cover over the section allows.

## References

- U.S. Bureau of Reclamation. Earth Manual, Part 2, 3rd ed. Denver: USBR, 1990.
- ASTM D4044/D4044M. Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifers. West Conshohocken: ASTM International.
- Hvorslev, M. J. Time Lag and Soil Permeability in Ground-Water Observations. Bulletin 36. Vicksburg: U.S. Army Corps of Engineers, Waterways Experiment Station, 1951.
- Bouwer, H., and Rice, R. C. A slug test for determining hydraulic conductivity of unconfined aquifers with completely or partially penetrating wells. Water Resources Research, 12(3), 423–428, 1976.
- Yang, S.-Y., and Yeh, H.-D. A simple approach using Bouwer and Rice's method for slug test data analysis. Ground Water, 42(5), 781–784, 2004.
- Houlsby, A. C. Routine interpretation of the Lugeon water-test. Quarterly Journal of Engineering Geology, 9(4), 303–313, 1976.
- Quiñones-Rozo, C. Lugeon test interpretation, revisited. In Collaborative Management of Integrated Watersheds, 30th Annual USSD Conference, Sacramento, 405–414, 2010.
- ABGE. Ensaios de permeabilidade em solos: orientações para sua execução no campo. Boletim 04, 3rd ed. São Paulo: ABGE, 1996.