Theory: Direct Shear
How the direct shear test measures a soil's strength, and how specimens tested under different normal stresses give the Mohr-Coulomb envelope.
The test
The specimen sits in a split box between porous stones and is consolidated under a constant normal stress. One half of the box is then pushed sideways at a constant rate, forcing failure on the plane between the two. The horizontal force and the displacements are recorded; the shear stress is the horizontal force over the contact area between the halves, which shrinks as the box moves.
Each specimen gives one point; the envelope needs at least three, under different normal stresses. As the rate is chosen so that no pore pressure builds up, the stresses are effective.
The import button reads the .csv files of the GeoFluxo laboratory's direct shear machine: it checks the name, the header and the columns, and uses only the shearing stage, with σ′ the median normal stress in it. Files in another layout are refused, with the reason, rather than read wrong. The table for typing or pasting works on its own, for any machine.
Shear stress at failure
It is the largest of each specimen's readings:
If the maximum is at the last reading and the final displacement is under 5 mm, the specimen may not have failed: the maximum would be the end of the equipment's travel, not the soil's. The app warns and takes that specimen out of the envelope; it can be ticked back in.
Mohr-Coulomb envelope
The (σ′, τf) pairs are fitted by a least-squares line:
Quality of the fit
R² alone doesn't say how much c′ and φ′ may vary. So the page also shows the standard error s, the typical distance of the points from the line, in kPa; the 95% intervals of c′ and φ′, with Student's t distribution of n − 2 degrees of freedom (with few points they are wide, and that is the right result); and each specimen's residual, how far its τmax lies above (+) or below (−) the line.
The “point off the line” warning appears when a specimen's residual, divided by the scatter of the others, exceeds 2 in absolute value, and only with 5 or more points. The shaded band around the line is the 95% band of the mean line, that is, where the envelope probably runs; it isn't the band where a new specimen would fall, which would be wider.
On this page
- Test per ASTM D3080, consolidated drained.
- A series is a set of specimens, such as one soil or one depth. The envelope is the open series'.
- One specimen per normal stress. Untick one to leave it out of the envelope without deleting it. Without readings, type its τmax. A comma or a point works as the decimal.
- The box's horizontal displacement and the shear stress of each reading, from the shearing stage only. Enter moves down a row; the two columns of a spreadsheet can be pasted.
The 3D is an illustration of a generic shear machine, with the 60 mm square box; it doesn't depend on the tests typed in.
Limitations
- The failure plane is imposed by the box, not the soil's weakest.
- In a soil that hardens to the end of the travel, with no peak, the maximum falls on the last reading and depends on how far the test was taken.
- Cemented material and natural soil should not go in the same envelope.
- With three points, one bad point changes the line a lot; check the points on the chart.
References
- ASTM D3080/D3080M. Standard Test Method for Direct Shear Test of Soils Under Consolidated Drained Conditions. West Conshohocken: ASTM International.
- Head, K. H. Manual of Soil Laboratory Testing. v. 2. Wiley.
- Pinto, C. S. Curso Básico de Mecânica dos Solos. São Paulo: Oficina de Textos.
- Das, B. M.; Sobhan, K. Principles of Geotechnical Engineering. 9th ed. Boston: Cengage, 2018.