# Dynamic Cone Penetrometer (DCP)

> Get the penetration index (DCPI) and in-place CBR of each pavement layer and the subgrade from DCP readings, by Webster (ASTM D6951) and Kleyn.

Interactive app: https://app.geofluxo.com/en-US/apps/dcp

Enter the hammer, the correlation and the dynamic cone penetrometer (DCP) readings, each with its blows and cumulative penetration, and the pavement or subgrade layers, to get the penetration index (DCPI, mm/blow) and the CBR of each interval and each layer, by Webster's correlations in ASTM D6951 or by Kleyn and Van Heerden's.

## Theory

How the dynamic cone penetrometer measures the penetration index of a pavement's layers and subgrade, and how the CBR is estimated from it.

### The test

The dynamic cone penetrometer (DCP) is a steel rod with a 60°, 20 mm cone at its tip, driven by an 8 kg hammer dropping 575 mm onto an anvil. Once the cone is seated, the scale is read (the zero reading) and then, every blow or every few blows, the cumulative penetration. The test is quick and light, and goes through a pavement's base, subbase and subgrade to about 1 m.

The lighter 4.6 kg hammer suits soft soils; each of its blows counts as half of the 8 kg hammer's, so ASTM D6951 doubles the blow count.

### Penetration index

$$
DCPI = \frac{z_i - z_{i-1}}{N_i \, f} \qquad DCPI_{layer} = \frac{z_{bottom} - z_{top}}{N_{bottom} - N_{top}}
$$

z: cumulative penetration (mm) · N<sub>i</sub>: blows between readings · f: 1 with the 8 kg hammer, 2 with the 4.6 kg · N: cumulative blows

On the penetration profile (depth against cumulative blows), each layer is a stretch of nearly constant slope, and the changes of slope mark the interfaces. A layer's DCPI is its thickness-weighted mean: its thickness over the blows it took.

### CBR correlations

ASTM D6951 gives the US Army Corps of Engineers' correlations by Webster et al. (1992, 1994), with the DCPI in mm/blow:

$$
CBR = \frac{292}{DCPI^{1.12}} \qquad CBR_{CL} = \frac{1}{(0.017019\,DCPI)^2} \qquad CBR_{CH} = \frac{1}{0.002871\,DCPI}
$$

General: all soils but lean clays (CL) of CBR under 10 and fat clays (CH)

Kleyn and Van Heerden (1983), in South Africa, for granular materials and pavement soils:

$$
\log CBR = 2.632 - 1.28 \log DCPI
$$



The correlations give the in-place CBR, at the soil's water content and density on the day, not the soaked laboratory CBR. Local correlations, calibrated for the soils at hand, should be preferred where they exist.

### On this page

- Each reading has the blows since the last one and the cumulative penetration from the surface. The first, with no blows, is the zero reading; with blows, it counts from the surface (z = 0).
- Each interval's DCPI is its penetration over its blows; its CBR uses the soil of the layer its midpoint is in.
- Layers are given by their bottoms, and each one's DCPI is its thickness over its blows, interpolated between the readings either side of the interface.
- With Webster's correlation, a CL soil uses its own equation only where it gives a CBR under 10; above, the general one. The soil doesn't change Kleyn's.
- The app stays metric: the correlations are defined in mm/blow, and the rod is graduated in millimeters.
- The CBR other apps take, such as the pavement design, is the last layer's, usually the subgrade.

The 3D is an illustration of the test: the layers the readings were split into, in tones only to tell them apart, and the penetrometer with its cone at the depth reached.

### Limitations

- Stones and large gravel stop or deflect the cone; under 2 mm in 5 blows is refusal, and the test should be moved over and repeated.
- The CBR depends on the soil's water content on the day: a subgrade tested dry may show a much higher CBR than in the wet season.
- Friction on the rod, deep or in clays, adds blows and underestimates the DCPI.
- The correlations scatter widely; they serve evaluation and control, and design should rest on laboratory tests too.

## References

- ASTM International. ASTM D6951/D6951M-18, Standard Test Method for Use of the Dynamic Cone Penetrometer in Shallow Pavement Applications. West Conshohocken, PA, 2018.
- Kleyn, E. G., and Van Heerden, M. J. J. (1983). Using DCP soundings to optimise pavement rehabilitation. Annual Transportation Convention, Johannesburg.
- Webster, S. L., Grau, R. H., and Williams, T. P. (1992). Description and Application of Dual Mass Dynamic Cone Penetrometer. Instruction Report GL-92-3, US Army Engineer Waterways Experiment Station, Vicksburg, MS.
- Webster, S. L., Brown, R. W., and Porter, J. R. (1994). Force Projection Site Evaluation Using the Electric Cone Penetrometer (ECP) and the Dynamic Cone Penetrometer (DCP). Technical Report GL-94-17, US Army Engineer Waterways Experiment Station, Vicksburg, MS.