Skip to content
Bearing Capacity

Theory · FND-03 · Foundations

Bearing Capacity of Shallow Foundations

Where the bearing capacity equation comes from, how Terzaghi, Meyerhof and Vesić differ, and how the footing's shape and depth, the load's inclination and eccentricity and the water table enter it.

Enter the footing — shape, width, depth, and the load's inclination and eccentricity — and the soil's c′, φ′ and unit weights to get the ultimate and allowable bearing capacity by Terzaghi, Meyerhof and Vesić, side by side, with each method's factors.

Bearing capacity failure

As the load on a footing grows, the soil under it fails in shear along a surface that runs from the footing's edges down and out to the ground. In general shear failure, typical of dense sand and stiff clay, the surface is well defined and the ground heaves beside the footing. In loose or soft soil the failure is local or by punching, with large settlement before any clear peak.

Prandtl (1921) described the mechanism for a strip: an active wedge pushed down under the footing, a radial fan bounded by a log spiral, and a passive Rankine wedge pushed up at each side. The bearing capacity is the pressure that brings this mechanism to failure.

Terzaghi's equation

Terzaghi (1943) split the ultimate bearing capacity into three terms — the soil's cohesion, the overburden beside the footing (treated as a surcharge q = γDf, with the soil above the base giving no strength) and the weight of the soil in the failure zone — each with a factor that depends only on φ′.

qu=c′Nc sc+qNq+12γBNγ sγq_u = c' N_c\, s_c + q N_q + \tfrac{1}{2} \gamma B N_\gamma\, s_\gamma
Strip: sc = sγ = 1 · square: sc = 1.3, sγ = 0.8 · circular: sc = 1.3, sγ = 0.6 (B the diameter)
Nq=e2(3π/4−ϕ′/2)tan⁡ϕ′2cos⁡2(45∘+ϕ′/2)N_q = \frac{e^{2\left(3\pi/4 - \phi'/2\right) \tan\phi'}}{2 \cos^2\left(45^\circ + \phi'/2\right)}
Nc=(Nq−1)cot⁡ϕ′N_c = (N_q - 1) \cot\phi'
Nγ has no closed form; Das uses Kumbhojkar's (1993) values. For φ′ = 0, Nc = 5.7

For local shear, Terzaghi suggested the same equation with c′ and tan φ′ reduced to two thirds.

Meyerhof and the general equation

Meyerhof (1963) took Prandtl and Reissner's Nc and Nq, with a rough-footing wedge at 45° + φ′/2, and added factors for the footing's shape, its depth (counting the shear strength of the soil above the base) and the load's inclination.

qu=c′Nc scdcic+qNq sqdqiq+12γB′Nγ sγdγiγq_u = c' N_c\, s_c d_c i_c + q N_q\, s_q d_q i_q + \tfrac{1}{2} \gamma B' N_\gamma\, s_\gamma d_\gamma i_\gamma
s: shape · d: depth · i: inclination factors
Nq=eπtan⁡ϕ′tan⁡2(45∘+ϕ′2)N_q = e^{\pi \tan\phi'} \tan^2\left(45^\circ + \frac{\phi'}{2}\right)
Nc=(Nq−1)cot⁡ϕ′N_c = (N_q - 1) \cot\phi'
Prandtl (1921) and Reissner (1924). For φ′ = 0, Nc = π + 2 = 5.14
Meyerhof (1963)Vesić / general equation
Nγ(Nq − 1) tan(1.4φ′)2(Nq + 1) tan φ′
sc1 + 0.2Kp B/L1 + (Nq/Nc)(B/L)
sq1 + 0.1Kp B/L1 + (B/L) tan φ′
sγ1 + 0.1Kp B/L1 − 0.4 B/L
dc1 + 0.2√Kp Df/B1 + 0.4 Df/B
dq1 + 0.1√Kp Df/B1 + 2 tan φ′(1 − sin φ′)2 Df/B
dγ1 + 0.1√Kp Df/B1
ic = iq(1 − β/90°)2(1 − β/90°)2
iγ(1 − β/φ′)2(1 − β/φ′)2

Kp = tan2(45° + φ′/2). Meyerhof's sq, sγ, dq and dγ hold from φ′ = 10°; below it they're taken as 1. In the general equation, Hansen's depth factors replace Df/B by arctan(Df/B) (in radians) when Df > B. The Nc and Nq of the two are the same; they differ in Nγ, Vesić's being the larger, and in the factors.

Water table

  • Above the base (Dw ≤ Df): q = γDw + γ′(Df − Dw), and the γ term takes the buoyant γ′ = γsat − γw.
  • Within B below the base (Df < Dw ≤ Df + B): q = γDf, and the γ term takes γ̄ = γ′ + (d/B)(γ − γ′), d being Dw − Df.
  • Deeper than Df + B: the water table doesn't affect the bearing capacity.

Eccentric loads

A load at an eccentricity e from the center is taken, after Meyerhof (1953), as centered on an effective footing of width B′ = B − 2e. The γ term and the shape factors use B′, and the load the footing can carry is qu over the effective area A′ = B′L.

Allowable bearing capacity

qall=quFSq_{\mathrm{all}} = \frac{q_u}{\mathrm{FS}}
Qall=qall A′Q_{\mathrm{all}} = q_{\mathrm{all}}\, A'
FS: factor of safety, usually 3 for shallow foundations

The allowable value also has to keep settlement within limits, which often governs on wide footings and in soft clays.

On this page

  • Homogeneous soil under the footing; the water table follows Das's three cases.
  • Terzaghi's Nγ is Kumbhojkar's (1993), as Das tabulates it. His shape factors are extended to rectangles linearly in B/L, and he has no depth or inclination factors.
  • Vesić's method is the general equation as in Das: Vesić's Nγ, De Beer's shape factors, Hansen's depth factors and Meyerhof's inclination factors.
  • An eccentric load is carried on Meyerhof's effective width B′ = B − 2e, used in the γ term, the shape factors and the area; depth factors use B.
  • qall = qu/FS on the gross bearing capacity.
  • β is the load's angle from the vertical; e is measured along B. Circular footings take centered loads.
  • Leave the water table blank when it's deeper than Df + B; it's measured from the ground surface.

The 3D is an illustration of the footing at its depth, with the column; the footing's thickness and the column are illustrative and don't enter the calculation.

References

  1. Terzaghi, K. Theoretical Soil Mechanics. New York: Wiley, 1943.
  2. Meyerhof, G. G. Some recent research on the bearing capacity of foundations. Canadian Geotechnical Journal, v. 1, n. 1, p. 16–26, 1963.
  3. Vesić, A. S. Analysis of ultimate loads of shallow foundations. Journal of the Soil Mechanics and Foundations Division, ASCE, v. 99, n. SM1, p. 45–73, 1973.
  4. Hansen, J. B. A revised and extended formula for bearing capacity. Danish Geotechnical Institute, Bulletin 28, 1970.
  5. Kumbhojkar, A. S. Numerical evaluation of Terzaghi's Nγ. Journal of Geotechnical Engineering, ASCE, v. 119, n. 3, p. 598–607, 1993.
  6. Das, B. M.; Sobhan, K. Principles of Geotechnical Engineering. 9th ed. Boston: Cengage, 2018.